3-Ton-R-454B-SEER2-Rheem-Select-Gas-System-Condenser-Coil-80-Gas-Furnace-01-jip

3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace

3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace
3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace
3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace
3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace
3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace
3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace

3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace
Are you looking for a different HVAC equipment size or type? For Monthly SPECIALS & Discounts check. Call For Availability Before Ordering. All Items Are New From the Factory. 3 – Ton 14.3 SEER2 R454B. Complete Gas Heating System. Evaporator Coil Model #. 80% Gas Furnace Model #. You are purchasing a brand NEW direct from the factory Gas Heating System Condensing Unit & Evaporator Coil & 80% Gas Furnace made by RHEEM. These units are NOT a scratch or dent item or a discontinued model. As you learn more about this great product, which we are offering at an even more incredible price, we are confident that you will not find a better bargain than this. We have more than 30 years’ experience in the industry and because of this, we are able to offer you this quality equipment at these affordable prices. Thank you in advance for shopping with us. WA14Y Endeavor ® Line Select T Series. Cooling Efficiencies up to: 15.2 SEER2 / 12 EER2 Refrigerant Type: R-454B. Fully Louvered Steel Cabinet: Features durable construction to add protection from yard hazards, weather corrosion. Optimized 7mm Coil Design: Allows for improved airflow, heat transfer and energy consumption. Easily Accessible Control Box: Ease of installation and serviceability. Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%1 lower GWP than previous-generation refrigerants – with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort. PlusOne® Refrigerant Detection SystemT2: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess refrigerant is detected. Rheem 80% Gas Furnace. W801T (UH) Gas Furnace – 80% A. Heating Stages: Single Stage, Motor Type: Constant Torque, Input Rates: 50-125 K BTU, Configuration Options: Upflow/Horizontal. Diagnostics: Industry-first, 7-segment LED for quick & easy service. Ignition System: Proven Direct Spark Ignition (DSI) for reliability and longevity. Low Profile, 34-inch Cabinet: Makes our furnaces ideal for space-constrained installations. Hemmed Cabinet & Door Edges and Quarter-Turn Door Fasteners (Upflow/Horizontal only): Allows for safe, toolless access and serviceability. Removable Heat Exchanger: Improves serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. 14 X 29.625 X 34. 17.5 X 29.625 X 45. 21 X 29.625 X 34. TCFY Cased Coils For Gas and Oil Furnaces. Refrigerant Type: R-454B Airflow Capacity: 600-1,900 CFM. These Indoor Furnace cased coils are designed for use with outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kW] to 60,000 BTU/HR 17.6 kW. Constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Feature two sets of 3/4 [19.1 mm] N. Condensate drain connections for ease of connection. Chatleff metering device connections, at inlet and outlet of TXV or EXV and equalizer connections (TXV only). Approved for system application with variety of outdoor units. Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material. Compatible with Germicidal Light System (UV resistant). Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right. Unique drain pan design maximizes application flexibility and condensate removal. N-Coil design maximizes performance and minimizes height required at installation. Coils are AHRI certified for system application with a variety of outdoor units. Refrigerant Detection SystemT : An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess refrigerant is detected. Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L). Split HVAC systems and components are designed to be installed by qualified HVAC technicians. The installation of HVAC systems includes electrical, gas, and refrigerant connections, is generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. Further, the failure to properly install HVAC equipment can raise personal safety and performance concerns. As outlined, the failure to comply with this policy could lead to violations of applicable law that are punishable by fines.
3 Ton R-454B SEER2 Rheem Select Gas System Condenser & Coil & 80% Gas Furnace